category:energy / date:2022-07-04 05:46:15 / browse:147 / comment:3

The water tank is designed to be separated from the machine body and is double-layer. It will not drip due to condensation caused by internal and external temperature difference. It can be interlocked with the refrigeration system, that is, it will not be humidified during refrigeration to prevent serious frosting of the fan.Whether the water pump works normally and whether the moldy switch is effective. In case of abnormality, timely handle the overhaul and maintenance of the refrigeration compressor in the cold storage: generally, the refrigeration oil and drying filter shall be replaced times after the operation of the cold storage equipment. Replacement after half a year. Depending on the circumstances.Vernon,The overall layout of the unit is reasonable and the color is. The installation structure of each type of unit shall be consistent.The closed cell structure and surface material of polyurethane rigid foam with good moisture-proof, waterproof and corrosion resistance make it have better air resistance and water vapor resistance and it can be made into inlaid connection structure during forming, which is easy to assemble. It does not need additional insulating layer to prevent moisture and saves a lot of trouble in laying insulating layer.Kifri,Moreover, polyurethane does not produce harmful gas at high temperature.Now let's analyze the production and use requirements of the cold storage. There is no condensation in the cold storage. Condensation in the cold storage or in the insulation layer is harmful. During the drying process of the new wall or under winter conditions, when the water vapor with high indoor temperature migrates outdoors, it is impossible to condense in the wall due to the obstruction of the cold storage.Step of cold storage design: define the volume of the cold storage warehouse. The size of the cold storage should be based on the design of a large number of agricultural products to be stored for a long time. This volume is calculated based on the essential volume of stored goods accumulated in the cold storage, plus the row to row corridors, the indoor space between the pile and the wall, the ceiling and the gap of the packaging house. After the volume of the cold storage is determined, such as working intermediate, packaging and combing room, special tool warehouse, loading and unloading platform, etc.


VernonWhich is a good refrigeratorSelect appropriate for different characteristics and uses



Artificial refrigeration keeps the room at a constant temperature. The walls, the surface of the external wall of the cold storage is painted white or light color.The cooler on the refrigeration unit is very easy to be dirty, so it should be cleaned on time according to the specific situation. To maintain stable heat conduction and practical effect. Good heat removal and cooling. There is no need to accumulate dirt around the refrigeration unit.Floor insulation of small cold storage the structure of small cold storage is usually called surface, the top, wall and ground are made of color steel plate / stainless steel with appropriate thickness of polyurethane and other insulation materials, because the loading and unloading of small cold storage is often handled manually rather than forklift. Of course,VernonTea cold storage, if the height of the warehouse is high and the forklift is required for warehousing, loading and unloading, the insulation board is not recommended for ground insulation, but the ground needs to be insulated separately like the ground insulation sample of medium-sized cold storage.Energy costs,After being stored in the medical cold storage project, ventilating medical products may also emit some odors. Once these odors are stored in a certain quantity, they will also have a certain impact on other products. Therefore, we must carry out regular ventilation in the process of daily use, so as to effectively reduce the storage time of products. If the medical cold storage project uses row tube refrigeration, the image of frosting may appear after use for a period of time. If we do not defrost in time, it will also affect the effect of. Therefore, I hope you must pay attention to defrosting.All wiring shall be neat. All switches and keys shall be opened and closed sensitively, reliably and accurately. Special connectors shall be used for wiring, and power protection shall be provided for the box and each power branch.During the installation of long-span top warehouse plate, if the supporting steel beam has been installed in the warehouse, the top warehouse plate and the supporting steel beam shall be fixed with pull rivets during the installation of each warehouse plate, and each top warehouse plate shall be riveted in two rows; If the lifting point type is adopted the installation and construction of the lifting layout shall be realized before the installation and construction of the top silo plate,VernonInstallation of cold storage, so as to ensure that each lifting point can be installed at the same time during the installation of the top silo plate; The lifting point shall ensure that there are at least two points along the width direction of each warehouse plate.


VernonWhich is a good refrigeratorSelect appropriate for different characteristics and uses



Points of multi-storey cold storage: small, which can save land; When the storage capacity is the same, the surface area of the outer enclosure structure is smaller than that of the single-layer cold storage, so that the cold consumption can be reduced, the dry consumption of food can be reduced, and the machinery and equipment cost and operation and management cost can be reduced accordingly. At the same time, due to the saving of thermal insulation materials, such as the cooling room can be used as the cold storage room, the attic on the top floor can be built into the ice making room, etc.DiscountThe products stored in the medical cold storage project must be managed by color code, so as to avoid the problem of purchase errors. In the process of handling, it is also necessary to strictly follow the instructions.After startup, first listen to whether the sound of the compressor is normal, and see whether the condenser and cooling fan operate normally.Improper adjustment or blockage of throttle valve, too large or too small refrigerant flow: improper adjustment or blockage of throttle valve will directly affect the refrigerant flow into evaporator. When the throttle valve is opened too large, the refrigerant flow is too large, the evaporation pressure and evaporation temperature also increase, and the decline rate of warehouse temperature will slow down; At the same time, when the throttle valve is opened too small or blocked the refrigerant flow will also decrease, the refrigeration capacity of the system will also decrease, and the decline rate of warehouse temperature will also slow down.Vernon,The quick-frozen warehouse is easy to load and unload. All the plates and walls of the quick-frozen warehouse are produced by molds. You can choose tens of millions of products. Professional cold storage installation,VernonWhere is the cold storage company, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage and transaction safety are guaranteed. Through internal concave convex groove connection, loading, unloading and handling are convenient. The installation period is short. Small and medium-sized cold storage can be delivered in - days, The library body can be combined, separated or increased or decreased according to the needs of users.According to the size and nature of the cold storage area and in combination with local regulations, the construction form of food cold storage warehouse is to determine the plane layout based on the site, whether it is a single-layer or double-layer warehouse, and the structure is the selection of steel structure or reinforcement solidification. Cold storage capacity, refrigeration, product stacking, temperature etc. are used to determine the size and location of the cold storage room, so that it can become a whole.In order to prevent damage to the cold storage, it is necessary to lay some foam on the floor of the cold storage tank.

Copyright Notice: This article is not authorized by any Creative Commons agreement, you can freely reprint or use it in any form

Comment area

share 3 Comments

user 717HP127443542 / 2022-07-04 12:53:35 / reply
The logistics is very fast, look forward to working together again
user 709HP180518493 / 2022-07-04 13:31:34 / reply
The first online purchase VernonWhich is a good refrigerator. I use my personal experience to tell everyone that your service attitude is very good. The quality of the goods is also very good. I like you!
user 263HP145816628 / 2022-07-04 12:56:53 / reply
VernonWhich is a good refrigerator The goods have arrived, much better than what you see in the picture!

Comment / Cancel reply

Required

Optional

Optional

◎Welcome to discuss, please express your views here.

Hello, welcome to this website!

Label list

Links